MicroSlide® Pediatric MST Introducer
For Smaller Patient Access, Keep It Short and Sweet
Indicated for Neonatal and Pediatric Use.
Introducer sheaths and accessories created by and for neonatal and pediatric clinicians.
Description
Atraumatic Neonatal and Pediatric Access
- Smaller sizes facilitate atraumatic vascular access in pediatrics and neonates as small as 500g1
- MicroSlide® helps eliminate multiple sticks and improve PICC insertion success in adults, pediatrics, and neonates1
- Using MicroSlide® MST reduces procedure time, procedure-related stress, and cost1
Range of Configurations for Procedural Success
- Available in 2F – 3F x 3cm and 2F x 7cm for tunneled procedures
- Sharp 24G needles in multiple lengths with echogenic tips
- Variety of guidewire options in several lengths and sizes from .008″ for PICC line insertion to .018″ compatibility for maximum support. Core/tip configurations include NiTi/NiTi with both short and long tapers for either pushability or atraumatic trackability and NiTi/Au for enhanced visibility
- All-inclusive packaging or separate sterile components
Ordering Information
Tearaway Introducer Kits
Catalog No. | Sheath Size | Guidewire Size |
Guidewire Material |
Echo Needle |
Box Quantity |
---|---|---|---|---|---|
KIT-051-00 | 2F x 3cm | .008″ x 20cm | NiTi/NiTi | 24G x 2.5cm | 5 |
KIT-051-01 | 2F x 3cm | .008″ x 40cm | NiTi/NiTi | 24G x 2.5cm | 5 |
KIT-051-02 | 2F x 3cm | .008″ x 20cm | NiTi/NiTi | 24G x 4cm | 5 |
KIT-051-03 | 2F x 3cm | .008″ x 40cm | NiTi/NiTi | 24G x 4cm | 5 |
KIT-051-04 | 3F x 3cm | .010″ x 20cm | NiTi/NiTi | 24G x 2.5cm | 5 |
KIT-051-05 | 3F x 3cm | .010″ x 40cm | NiTi/NiTi | 24G x 2.5cm | 5 |
KIT-051-06 | 3F x 3cm | .010″ x 20cm | NiTi/NiTi | 24G x 4cm | 5 |
KIT-051-11 | 3F x 3cm | .010″ x 40cm | NiTi/NiTi | 24G x 4cm | 5 |
KIT-051-13 | 2F x 3cm | .014″ x 20cm | NiTi/Au | 24G x 4cm | 5 |
KIT-051-14 | 2F x 3cm | .014″ x 40cm | NiTi/Au | 24G x 4cm | 5 |
Kits and Sets (set = sheath/dilator assembly only)
Tearaway Introducer Sets
Catalog No. | Sheath Size | Accepts Guidewire |
Box Quantity |
---|---|---|---|
INT-101-02 | 2F x 3cm | .008″ | 10 |
INT-101-14 | 2F x 3cm | .014″ | 10 |
INT-101-15 | 2F x 7cm | .014″ | 10 |
INT-101-03 | 3F x 3cm | .018″ | 10 |
Set Contents: PTFE Sheath and Dilator only
Guidewires
Catalog No. | Sheath Size | Guidewire Material | Box Quantity |
---|---|---|---|
SGW-051-06 | .008″ x 20cm | NiTi/NiTi | 5 |
SGW-051-08 | .008″ x 40cm | NiTi/NiTi | 5 |
SGW-051-03 | .008″ x 60cm | NiTi/NiTi | 10 |
SGW-051-07 | .010″ x 20cm | NiTi/NiTi | 5 |
SGW-051-09 | .010″ x 40cm | NiTi/NiTi | 5 |
SGW-051-04 | .010″ x 60cm | NiTi/NiTi | 10 |
SGW-056-62 | .014″ x 20cm | NiTi/Au | 5 |
SGW-056-60 | .014″ x 40cm | NiTi/Au | 5 |
Needles
Catalog No. | Size | Length | Tip | Box Quantity |
---|---|---|---|---|
NDL-100-29 | 24G | 2.5cm | Echogenic | 25 |
NDL-100-30 | 24G | 4cm | Echogenic | 25 |
References
1. Improving Neonatal Peripherally Inserted Central Catheter (PICC) Insertion: The Use of Modified Seldinger Technique (MST). Holly A. Hess, RN, BSN, VA-BC, Pediatric/Neonatal Vascular Access Specialist